Ticket #2186 (closed defect: duplicate)

Opened 6 years ago

Last modified 6 years ago

No support for maxim 6635

Reported by: ticket Owned by: somebody
Priority: major Milestone:
Component: hardware Version: 2.10.1
Keywords: Cc: astranaut_@…

Description

Hi

My last report were  http://www.lm-sensors.org/ticket/2167. I tried the new released version 2.10.2 and nothing changed. sensors-detect tells:

Client found at address 0x44
Probing for `Maxim MAX6633/MAX6634/MAX6635'...No

A test with modprobe lm90 force_max6657=0,0x4c like described in your devices list results in:

max6657-i2c-0-4c
Adapter: SMBus I801 adapter at 18c0
M/B Temp: +0°C (low = +0°C, high = +0°C)
CPU Temp: +0.0°C (low = +0.0°C, high = +0.0°C)
M/B Crit: +0°C (hyst = +0°C)
CPU Crit: +0°C (hyst = +0°C)

Is there a chance to get any response this time? What can I do to get more than the CPU temperature? Please help.

Change History

Changed 6 years ago by ruik

  • status changed from new to closed
  • resolution set to duplicate

Hello

SOrry I'm the only one doing the support right now, Jean is busy with maintaining the i2c stuff and we have also real life too (and regular job), I tried to answer in old ticket. Most likely you will need to use ACPI to get the temp, or get the coretemp driver (iirc) If you want to join the project let us know ;)

Rudolf

Note: See TracTickets for help on using tickets.