Changeset 6012

Show
Ignore:
Timestamp:
01/14/12 20:56:13 (3 years ago)
Author:
khali
Message:

w83627ehf: Increase default value of Vbat max, the previous default
triggered an alarm on many boards.

Files:
1 modified

Legend:

Unmodified
Added
Removed
  • lm-sensors/trunk/etc/sensors.conf.default

    r5977 r6012  
    324324    set in7_max  3.3 * 1.10 
    325325    set in8_min  3.0 * 0.90 
    326     set in8_max  3.0 * 1.10 
     326    set in8_max  3.3 * 1.10 
    327327 
    328328 
     
    341341    set in7_max  5.0 * 1.10 
    342342    set in8_min  3.0 * 0.90 
    343     set in8_max  3.0 * 1.10 
     343    set in8_max  3.3 * 1.10 
    344344 
    345345